Manual
Completed
Safety components
Safety components
To prevent personal injury, the machine is equipped with various fixed or movable guards as listed below.
TAll of these guards must be properly installed BEFORE the machine is used..
5-axis machining center
Door to the machining area, interlocking with Sick key
Access gate to the SCARA area, interlocking with Sick key
Sliding partition wall separating the machining area/SCARA area, PILZ safety sensor
Rear cover, fixed guard
Lockable electrical cabinet door with bit key
Lockable pneumatic cabinet door with square key
Emergency stop
Machine zones
Illustration 12: Machine zones
machining area (green)
scara zone (red)
mechanical zone (blue)
Zones 1 and 2 are machine-secure zones. They are separated by the sliding partition that allows access to one area while keeping the other one operational.
Mechanical zone 3 is only accessible in repair and maintenance mode by securing the energy supplies and removing the fixed guards.