ID | Alarm |
1 | 24 VDC power supply faulty
|
2 | 24 VDC circuit breaker faulty |
3 | UPS faulty/Machine power supply OUT |
11 | Emergency stop pressed |
12 | Door(s) open |
21 | Temperature of electrical box too high (> 50 °C) |
22 | Air pressure too low (< 4 bar) |
31 | Drive M1 faulty |
32 | Drive M1 faulty |
33 | Drive M2 faulty |
34 | Drive M3Z faulty |
35 | Drive M4 faulty |
36 | Partition drive faulty |
41 | Axes moving with pallet unclamped |
42 | Spindle turning with tool unclamped |
43 | Spindle temperature exceeded |
44 | X axis current exceeded |
45 | Y axis current exceeded |
46 | Z axis current exceeded
|
47 | B axis current exceeded
|
48 | C axis current exceeded
|
49 | Spindle current exceeded
|
50 | Spindle speed 0 %. |
51 | Tool change error: Distance and/or time of use exceeded |
52 | Tool change error: Same tool requested |
53 | Tool change error: A tool is in the spindle |
54 | Tool change error: No tool is in the spindle |
55 | Tool change error: Probe held in the spindle |
56 | Tool change error: CNC or SCARA not working |
57 | Tool change error: SCARA or partition in manual mode |
58 | Tool change error: Tool not found |
59 | Tool change error: Unable to insert the tool or time exceeded |
60 | Tool change error: Sequence stopped by operator |
61 | Tool change error: Wait until spindle temperature below 55 °C |
66 | Disk change error: Unable to pick up/set down the disk |
67 | Disk change error: Sequence stopped by operator |
68 | Disk change error: All disks are full |
71 | Pallet magazine not configured |
72 | Board change error: CNC or SCARA not working |
73 | Board change error: SCARA or partition in manual mode |
74 | Board change error: Plate cannot be changed |
75 | Board change error: Sequence stopped by operator |
76 | Board change error: Plate magazine full |
81 | Probe change error: CNC or SCARA not working |
82 | Probe change error: SCARA or partition in manual mode |
83 | Probe change error: A tool is detected in the spindle before the probe is loaded |
84 | Probe change error: The probe is not detected in the spindle |
85 | Probe change error: Probe cannot be loaded into the spindle |
86 | Probe change error: Probe cannot be inserted or time exceeded |
87 | Probe change error: Sequence stopped by operator |
91 | Tool check error: The configuration is incorrect |
92 | Tool check error: The sequence is incorrect |
93 | Tool check error: Sequence stopped by operator |
96 | Tool breakage: Test not in order |
97 | Tool breakage: Test not performed within the time limit
|